Fixed! Problem with surface elements in range Wolf.

In this article, you will find a solution for solving problems with surface elements, or if be precise, we will explain how to replace surface elements in range Wolf. You need to replace the radiant surface when it's damaged or it doesn't heat even though it's receiving the right voltage through the surface element switch. Process of replacing isn’t complicated, so you can do it even without experience. For this replacing you will need some tools: Phillips screwdriver, pliers, work gloves, sturdy prop such as a heavy stick or piece of wood. If you’re ready, we can begin. 

  1. Unplug the range or shut off the circuit breakers for the range. 
  2. Open the oven door completely and remove the screws from the bottom front lip of the glass cooktop frame. Carefully pull the cooktop assembly slightly forward to release the front lip of the glass cooktop frame from the front cabinet support bracket. Raise the front of the cooktop slightly to release the frame sides from the front support bracket then pull the cooktop forward to release the hinge tabs from the slots in the backguard. Lift the front edge of the glass cooktop and prop it open. Place the prop at the front of the range under the center of the cooktop’s front lip where it's steady, so the cooktop won't fall. Avoid damaging the oven cavity insulation when propping open the glass cooktop.
  3. To release a front surface element: Without disturbing the prop, carefully remove the screws from the front surface elements’ support bracket and lower the front elements and bracket onto the oven insulation. To release a rear surface element, first release the front surface elements as just described and then continue with these steps: Carefully remove the screws from the rear surface elements’ support bracket and lower the rear elements and bracket onto the oven insulation. Carefully remove the prop and lift the ceramic glass cooktop assembly up and off the range so you have room to replace the rear surface element.
  4. Mark the mounting holes on the support bracket so you can reinstall the mounting clips in the same holes when you install the new element. Using pliers, release the element’s mounting clips from the support bracket. Transfer the wires one at a time from the existing surface element to the new surface element. Transfer the surface element mounting clips from the existing surface element to the new surface element. Attach the new element to the mounting bracket.
  5. If you’re replacing a front surface element, attach the front surface elements’ support bracket and elements to the cooktop. If you’re replacing a rear surface element, place the cooktop on the top of the range and prop it up securely. Attach the rear surface elements’ support bracket and surface elements to the cooktop. Repeat the process to attach the front surface elements.
  6. Carefully remove the prop and lower the cooktop. Tuck the front lip of the cooktop frame under the front cabinet support bracket and lower the sides of the cooktop frame over the ends of the front support bracket. Push the cooktop back, inserting the hinge tabs into the backguard slots. Reinstall the mounting screws in the front lip of the cooktop frame. Close the oven door.
  7. Plug the range back into the electrical wall outlet or turn on the house circuit breakers for the range. If you pulled out the range to unplug it, push the range into position and ensure that the rear leveling foot properly engages with the anti-tip bracket so the range doesn’t fall forward when you open the oven door and pull out a loaded oven rack.

Fixed! Problem with the surface element is solved. All you need is to take some tests. If it works normally - you made everything right. Feel difficulties during replacing? Don’t hesitate to contact our customer support and arrange a meeting!


November 26, 2023

AC is leaking from the coil – HVAC Troubleshooting in San Diego

Have you encountered a leaking air conditioner? This causes not the most pleasant feelings and deprives you of comfort. Before solving this problem, you should determine what exactly became the source of the air conditioner flow.
HVAC Repair
November 26, 2023

Cracked Evaporator Coil – AC Repair in San Marcos

The need to carry out complex diagnostics of the air conditioner most often arises when the unit does not turn on, or there is some irregularity in the operation of the air conditioning equipment.
HVAC Repair
November 26, 2023

Carrier AC Fan Won’t Work – HVAC Maintenance in Carlsbad

A comfortable temperature is a critical component that influences pleasant work in an office space and relaxation in the room. A malfunction in the air conditioner becomes a real problem for the system owner. One of the most popular malfunctions is a lifeless external air conditioner unit fan.
HVAC Repair
November 26, 2023

No air coming out of the vent – AC Repair in San Diego

One of the most common problems homeowners face is the supply of warm air from the air conditioner. This problem can catch you by surprise and cause not the most pleasant feelings, especially if it happens on a sweltering day.
HVAC Repair
November 26, 2023

AC Control Panel is Blank – HVAC Inspection in San Diego

It is often the case that a certain breakdown detected in the device can have several causes of origin. At the same time, the root cause of the malfunction does not always lie in the element in which it first appears.
HVAC Repair
November 22, 2023

AC Diagnostics in San Diego

The purpose of servicing air conditioners is to maintain the technical characteristics of the air conditioner in a given range of values, as well as to eliminate malfunctions that occur during equipment operation.
HVAC Repair
November 22, 2023

Carrier A/C Isn’t Working – HVAC Diagnostics in Folsom

Several symptoms alert about an air conditioner breakdown. No cooling, frequent cycling on and off, noises, hot or warm air blowing are among them. If you suspect your Carrier A/C in functioning incorrectly, it will be reasonable to arrange a maintenance visit.
HVAC Repair
November 22, 2023

Goodman AC isn’t working – AC System Repair in Escondido

The owner of this Goodman AC system has complained about a refrigerant leak. The refrigerant pressure on the working system is below 30 Psig when it should be 60 Psig for the proper cooling effect. Refrigerant refill may solve the issue only temporarily. A Prime Air Solutions expert can offer either to find the leak and fix it or to replace the broken component.
HVAC Repair
November 22, 2023

AC Maintenance job in La Mesa

Timely maintenance of air conditioners guarantees the equipment’s long and high-quality functioning and its long life. It also saves on maintenance, and most importantly, it ensures the health and well-being of everyone using the equipment.
HVAC Repair
November 22, 2023

Carrier AC is noisy and not blowing – HVAC Tune-up in San Diego

Air conditioners have a moderate noise level; the usual buzzing is a variant of the norm. But a sharp increase in the sound level, as well as the appearance of unusual noises, on the contrary, should alert the owner. This is a sign of the need to diagnose the air conditioner immediately.
HVAC Repair
November 22, 2023

Carrier HVAC system is not turning off – AC Repair in San Diego

Oops! Your HVAC system is not turning off after using heat for the first time since last year. No panic! Prime Air Solutions technicians reveal that it's rather common for heating systems. It could be as simple as a broken thermostat or an electrical problem.
HVAC Repair
November 22, 2023

A/C Inspection in Ramona

Air conditioning systems are designed to improve the climatic conditions in residential and public spaces, and they do a good job of it. However, over time, the efficiency of climate technology decreases. This happens due to dust settling on radiators and filters, a drop in refrigerant pressure, wear of parts, or other reasons.
HVAC Repair
November 19, 2023

Furnace isn’t working – HVAC Maintenance in Sacramento

When your furnace doesn’t come on, it can be due to complicated or very simple reasons. If thermocouples, wiring, heat exchangers, or blower motors' performance is in doubt, it's better to contact a qualified professional. Professional check-up quickly shows the real reason for the trouble.
Furnace
November 19, 2023

Midea A/C is leaking – HVAC Diagnostics in Ramona

Water from the air conditioner can drip from both indoor and outdoor units. When the air conditioner operates in cooling mode, condensation forms on the internal heat exchanger, flows into the drainage bath, and goes through the drainage pipe to the street or the sewer. If the drain channel is clogged, the drainage basin fills up, and water leaks onto the walls.
HVAC Repair
November 19, 2023

AC Won’t Heat – AC Maintenance in Carmichael

If your heater turns on but refuses to heat the air, it is better to have a check-up. A dirty or clogged inducer motor may result in reduced airflow. This can lead to inadequate venting of combustion gases, potentially causing safety concerns. Additionally, reduced airflow might impact the overall efficiency of the heating system.