Once you determine the problem with your AC/heat pump, it’s necessary to cope with that as soon as possible. In some cases, there are issues you can prevent and problems you can solve on your own when you are aware of the heat pump troubleshooting steps. The owner often meets a situation when a condensing unit fan is running but an indoor fan isn’t working. If the outside unit starts, but your furnace or air handler isn’t blowing air, then test all the parts below to track the root of evil. Test the blower motor first of all. Inspect the capacitor, and if it is leaking oily fluid, is bulging or shows burn marks, it has failed and must be replaced. Test the run capacitor using a multimeter and determine if it is getting power and has a reading within 5-7 percent of the rating listed on the capacitor, and if it isn’t, the part is burned out and must be replaced. Test the furnace/air handler control board as discussed in the previous repair to see if it needs to be reset or replaced. Remember that you must be confident in all your actions and use all required equipment. Because repairing your HVAC unit involves your home's electrical system, call a licensed electrician if you feel uncomfortable with any aspect of electrical work, especially with testing the parts.

November 26, 2023
AC is leaking from the coil – HVAC Troubleshooting in San Diego
Have you encountered a leaking air conditioner? This causes not the most pleasant feelings and deprives you of comfort. Before solving this problem, you should determine what exactly became the source of the air conditioner flow.