Solved! Refrigerator Thermador KBUDT4260A02 isn’t cooling

Not cooling the refrigerator - is a problem. Meals might go bad with the wrong temperature. So if you find your Thermador KBUDT4260A02 not cooling well - recommend you, to fix that problem ASAP. In most cases to solve the problem, you need to replace the evaporator fan motor. The evaporator fan motor draws air over the evaporator (cooling) coils and circulates it throughout the refrigerator and freezer compartments. If the evaporator fan is not working, it will not circulate the cold air to the refrigerator compartment. If this occurs, the freezer may still get cold, while the refrigerator will not get cold. So you need to replace it. Follow our simple guide step-by-step. Prepare some tools - work gloves, nut driver set. 

  1. Remove the freezer shelf. Unplug the power cord from the wall outlet.
  2. Remove the spacer in the freezer shelf. Push the shelf to the left to release the right side of the shelf from the holes. Pull the shelf out of the freezer.
  3. Remove the mounting screws from the evaporator cover. Pull the top of the evaporator cover down and unplug the evaporator fan wire harness. Push the evaporator cover to the left side of the freezer and disconnect the green ground wire and the ice maker wire harness from the evaporator cover. Pull the evaporator cover out of the freezer and lay it on a work surface.
  4. Remove the metal locking rings from the two upper tabs on the back of the fan cover. Push the evaporator fan cover up and disengage the 4 locking tabs. Remove the evaporator fan cover.
  5. Pull the fan blade off the motor shaft. Lift the 2 locking tabs on the fan motor retainer. Rotate the motor retainer counter-clockwise pull it off. Lift the motor out of the mounting bracket.
  6. Place the new fan motor in the mounting bracket. Reinstall the motor retainer and rotate it clockwise, engaging the two locking tabs in the mounting bracket. Reinstall the fan blade on the motor shaft.
  7. Position the evaporator fan cover on the front of the evaporator cover and push the 4 tabs through the rectangular slots. Push the evaporator fan cover down into position. Reinstall the metal locking rings on the two top fan cover tabs.
  8. Position the evaporator cover in the freezer compartment and reconnect the ice maker wire harness and ground wire. Push the evaporator cover to the center of the freezer compartment and reconnect the evaporator fan wire harness. Position the evaporator cover over the evaporator and reinstall the mounting screws.
  9. Push the shelf into the mounting holes on the left side of the freezer compartment wall. Slide the shelf to the right and reinstall the shelf spacer.
  10. Plug in the refrigerator to restore power.

Here we are! You have replaced the evaporator fan motor in your Thermadorr fridge. If you feel difficult during the process and need some help, don’t hesitate to contact our customer support and arrange a meeting! 


November 26, 2023

AC is leaking from the coil – HVAC Troubleshooting in San Diego

Have you encountered a leaking air conditioner? This causes not the most pleasant feelings and deprives you of comfort. Before solving this problem, you should determine what exactly became the source of the air conditioner flow.
HVAC Repair
November 26, 2023

Cracked Evaporator Coil – AC Repair in San Marcos

The need to carry out complex diagnostics of the air conditioner most often arises when the unit does not turn on, or there is some irregularity in the operation of the air conditioning equipment.
HVAC Repair
November 26, 2023

Carrier AC Fan Won’t Work – HVAC Maintenance in Carlsbad

A comfortable temperature is a critical component that influences pleasant work in an office space and relaxation in the room. A malfunction in the air conditioner becomes a real problem for the system owner. One of the most popular malfunctions is a lifeless external air conditioner unit fan.
HVAC Repair
November 26, 2023

No air coming out of the vent – AC Repair in San Diego

One of the most common problems homeowners face is the supply of warm air from the air conditioner. This problem can catch you by surprise and cause not the most pleasant feelings, especially if it happens on a sweltering day.
HVAC Repair
November 26, 2023

AC Control Panel is Blank – HVAC Inspection in San Diego

It is often the case that a certain breakdown detected in the device can have several causes of origin. At the same time, the root cause of the malfunction does not always lie in the element in which it first appears.
HVAC Repair
November 22, 2023

AC Diagnostics in San Diego

The purpose of servicing air conditioners is to maintain the technical characteristics of the air conditioner in a given range of values, as well as to eliminate malfunctions that occur during equipment operation.
HVAC Repair
November 22, 2023

Carrier A/C Isn’t Working – HVAC Diagnostics in Folsom

Several symptoms alert about an air conditioner breakdown. No cooling, frequent cycling on and off, noises, hot or warm air blowing are among them. If you suspect your Carrier A/C in functioning incorrectly, it will be reasonable to arrange a maintenance visit.
HVAC Repair
November 22, 2023

Goodman AC isn’t working – AC System Repair in Escondido

The owner of this Goodman AC system has complained about a refrigerant leak. The refrigerant pressure on the working system is below 30 Psig when it should be 60 Psig for the proper cooling effect. Refrigerant refill may solve the issue only temporarily. A Prime Air Solutions expert can offer either to find the leak and fix it or to replace the broken component.
HVAC Repair
November 22, 2023

AC Maintenance job in La Mesa

Timely maintenance of air conditioners guarantees the equipment’s long and high-quality functioning and its long life. It also saves on maintenance, and most importantly, it ensures the health and well-being of everyone using the equipment.
HVAC Repair
November 22, 2023

Carrier AC is noisy and not blowing – HVAC Tune-up in San Diego

Air conditioners have a moderate noise level; the usual buzzing is a variant of the norm. But a sharp increase in the sound level, as well as the appearance of unusual noises, on the contrary, should alert the owner. This is a sign of the need to diagnose the air conditioner immediately.
HVAC Repair
November 22, 2023

Carrier HVAC system is not turning off – AC Repair in San Diego

Oops! Your HVAC system is not turning off after using heat for the first time since last year. No panic! Prime Air Solutions technicians reveal that it's rather common for heating systems. It could be as simple as a broken thermostat or an electrical problem.
HVAC Repair
November 22, 2023

A/C Inspection in Ramona

Air conditioning systems are designed to improve the climatic conditions in residential and public spaces, and they do a good job of it. However, over time, the efficiency of climate technology decreases. This happens due to dust settling on radiators and filters, a drop in refrigerant pressure, wear of parts, or other reasons.
HVAC Repair
November 19, 2023

Furnace isn’t working – HVAC Maintenance in Sacramento

When your furnace doesn’t come on, it can be due to complicated or very simple reasons. If thermocouples, wiring, heat exchangers, or blower motors' performance is in doubt, it's better to contact a qualified professional. Professional check-up quickly shows the real reason for the trouble.
Furnace
November 19, 2023

Midea A/C is leaking – HVAC Diagnostics in Ramona

Water from the air conditioner can drip from both indoor and outdoor units. When the air conditioner operates in cooling mode, condensation forms on the internal heat exchanger, flows into the drainage bath, and goes through the drainage pipe to the street or the sewer. If the drain channel is clogged, the drainage basin fills up, and water leaks onto the walls.
HVAC Repair
November 19, 2023

AC Won’t Heat – AC Maintenance in Carmichael

If your heater turns on but refuses to heat the air, it is better to have a check-up. A dirty or clogged inducer motor may result in reduced airflow. This can lead to inadequate venting of combustion gases, potentially causing safety concerns. Additionally, reduced airflow might impact the overall efficiency of the heating system.